INFRARED VENT-FREE PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Model: CGP10R
®
Save this manual for future reference.
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service
agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Model: CGP10R

INFRARED VENT-FREE PROPANE/LP GAS HEATEROWNER’S OPERATION AND INSTALLATION MANUALModel: CGP10R®Save this manual for future reference.WARNING: If the i

Page 2 - CONTENTS

101018662. Mark two mounting screw locations on wall (see Figure 5).INSTALLING HEATER TO WALLMarking Screw Locations1. Determine where you will locate

Page 3 - INFORMATION

11101866Installing Two Mounting ScrewsNote: Wall anchors and mounting screws are in hardware package. The hardwarepackage is provided with heater.Atta

Page 4

12101866Placing Heater On Mounting Screws1. Locate two keyhole slots on back panel of heater (see Figure 9).2. Place large openings of slots over scre

Page 5 - VENTILATION

13101866CONNECTINGTO GASSUPPLYNOTICEA qualified service person must connect heater to gas supply.Follow all local codes.The installer must supply an e

Page 6

14101866IMPORTANT: Hold pressure regulator with wrench when connecting it to gaspiping and/or fittings.Figure 13 - Gas Connection* An A.G.A. design

Page 7

151018663. Pressurize supply piping system by either using compressed air oropening propane/LP supply tank valve.4. Check all joints of gas supply pip

Page 8

16101866OPERATINGHEATERFOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS1. STOP! Read the safety information above.2. Make sure manual shutoff

Page 9

171018664. Wait five (5) minutes to clear out any gas. Then smell for gas, includingnear the floor. If you then smell gas, STOP! Follow “B” in the saf

Page 10 - WARNING

18101866TO SELECT HEATING LEVELFigure 18 - Burner Patterns1. Slightly press in control knob and turn counterclockwise C-clockwise to theLOW or HIGH po

Page 11 - INSTALLING TO

19101866INSPECTINGBURNERGRH/OV 007GOOD PILOT/LPThermocoupleCheck pilot flame pattern and burner flame pattern often.PILOT FLAME PATTERNFigure 19 shows

Page 12

2101866CONTENTSSECTION PAGESafety Information ... 2Product Identification ...

Page 13 - WARNING ICON G 001

20101866If burner flame pattern is incorrect, as shown in Figure 22• turn heater off (see To Turn Off Gas to Appliance, page 19)• see Troubleshooting,

Page 14 - CAUTION

21101866CLEANINGANDMAINTENANCEWARNING ICON G 001 WARNINGTurn off heater and let cool before cleaning.ContinuedWARNING ICON G 001 CAUTIONYou must keep

Page 15 - Continued

22101866REMEDY1. Turn on gas supply oropen manual shutoffvalve2. Turn control knob toPILOT position3. Press in control knobwhile in PILOT posi-tion4.

Page 16

23101866REMEDY1. Clean burner orifice(s)(see Cleaning andMaintenance, page 21)or replace burnerorifice(s)2. Replace burner orifice(s)3. Contact local

Page 17 - OPERATING

24101866TROUBLE-SHOOTINGContinuedTECHNICALSERVICEYou may have further questions about installation, operation, or troubleshooting.If so, contact DESA

Page 18 - TO SELECT HEATING LEVEL

25101866Btu (Variable) 5,500/10,000Type Gas Propane/LP OnlyIgnition PiezoPressure Regulator Setting 8" W.C.Inlet Gas Pressure (inches of water)Ma

Page 19 - MANUAL LIGHTING PROCEDURE

26101866PARTSCENTRALSThese Parts Centrals are privately owned businesses. They have agreed to supportour customer’s needs by providing original replac

Page 20 - INSPECTING

27101866PARTS LISTCGP10RThis list contains replaceable parts used in your heater. When ordering parts, followthe instructions listed under Replacement

Page 21

KEEP THIS WARRANTYWARRANTY INFORMATIONAlways specify model and serial numbers when communicating with the factory.We reserve the right to amend these

Page 22 - SHOOTING

3101866SAFETYINFORMATIONContinuedWARNING ICON G 001 WARNINGS ContinuedWARNING: Any change to this heater or its controls can be dangerous.1. This appl

Page 23

4101866PRODUCTIDENTIFICATIONPRODUCTFEATURESSafety DeviceThis heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS).The ODS/pilot is

Page 24 - TECHNICAL

5101866AIR FORCOMBUSTIONANDVENTILATIONWARNING ICON G 001 WARNINGThis heater shall not be installed in a confined space unlessprovisions are provided f

Page 25 - REPLACEMENT

6101866AIR FORCOMBUSTIONANDVENTILATIONContinuedDETERMINING AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this

Page 26 - PUBLICATIONS

7101866AIR FORCOMBUSTIONANDVENTILATIONContinuedFigure 2 - Ventilation Air from Inside BuildingOr Remove Door into Adjoining Room, Option 3Ventilation

Page 27 - BREAKDOWN

8101866AIR FORCOMBUSTIONANDVENTILATIONContinuedFigure 3 - Ventilation Air from OutdoorsOutletAirVentilatedAttic OutletAirInletAirInlet AirVentilated C

Page 28 - WARRANTY INFORMATION

9101866INSTALLING TOWALLNOTICEA qualified service person must install heater. Follow all local codes.CHECK GAS TYPEUse only propane/LP gas. If your ga