SOLID STATE IGNITION
50 60 70 80 90
50 60 70 80 90
DYNAVENT
WINDOW WALL FURNACE
DIRECT-VENT PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
DNV25PB
DNV40PB
25,000 and 40,000 BTU/Hr “B” Model Furnaces
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
WARNING: Improper in-
stallation, adjustment,
alteration, service, or
maintenance can cause
injury or property dam-
age. Refer to this manual
for correct installation
and operational proce-
dures. For assistance or
additional information
consult a qualified in-
staller, service agency,
or the gas supplier.
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Installation and ser-
vice must be performed
by a qualified installer,
service agency, or the
gas supplier.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
Page view 0
1 2 3 4 5 6 ... 29 30

Summary of Contents

Page 1 - DYNAVENT

Save this manual for future reference.SOLID STATE IGNITION50 60 70 80 9050 60 70 80 90DYNAVENTWINDOW WALL FURNACEDIRECT-VENT PR

Page 2

10201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®INSTALLATION(Continued)Installation must include an equipmentshutoff valve (supplied), ground joint

Page 3

11201839OWNER’S MANUALTest Pressures Equal To or Less Than1/2 PSIG (3.5 kPa)1. Close equipment shutoff valve (see Fig-ure 16).2. Pressurize supply pip

Page 4

12201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT® WARNING: Furnace burner,combustion chamber, and ex-haust port are very hot duringoperation. Keep ch

Page 5

13201839OWNER’S MANUALOPERATINGFURNACE(Continued)1. Set thermostat to lowest setting2. Turn equipment gas valve clockwise to OFF position. Do not forc

Page 6

14201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT® WARNING: Turn off and un-plug furnace and let cool beforecleaning. Turn equipment shutoffvalve to

Page 7

15201839OWNER’S MANUALTROUBLESHOOTING WARNING: Turn off and unplug furnace and let cool before servic-ing. Unless you need gas supply for testing, shu

Page 8

16201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®TROUBLESHOOTINGContinuedwww.desatech.comThe electronic system is made up of twoparts: the ignition c

Page 9

17201839OWNER’S MANUALwww.desatech.comOBSERVED PROBLEMIgnition failuresPOSSIBLE CAUSE1. Glo bar will not glow - with blower run-ning and microswitch e

Page 10

18201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®www.desatech.comOBSERVED PROBLEMIgnition failuresExcessive noiseMain burner will not cycle offFurnac

Page 11 - OWNER’S MANUAL

19201839OWNER’S MANUAL1234567JunctionBoxBlackGreen▲WhiteBlackWhiteWhiteBlackTransformerWhiteBrownBrownBlackMotorGreen370 V.A.C.Capacitor5 MFDTerminal

Page 12

2201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®6. This furnace must have fresh air for properoperation. If not, poor fuel combustion andimproper ven

Page 13

20201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®These Parts Centrals are privately owned businesses. They have agreed to support ourcustomer’s needs

Page 14

21201839OWNER’S MANUALKEY PARTNO. NUMBER DESCRIPTION QTY.1 030643 Front Cover Assembly 12 121520 Screw, #8 x 3/8" ** 23 191240 Front Cover Trim*

Page 15

22201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®ILLUSTRATEDPARTS LISTCABINET ASSEMBLY40,000 BTU/HR MODELThis list contains replaceable parts used in

Page 16

23201839OWNER’S MANUALILLUSTRATEDPARTS LISTCOMBUSTION CHAMBERASSEMBLY25,000 BTU/HR MODELThis list contains replaceable parts used in your furnace. Whe

Page 17

24201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®ILLUSTRATEDPARTS LISTCOMBUSTION CHAMBERASSEMBLY40,000 BTU/HR MODELThis list contains replaceable par

Page 18

25201839OWNER’S MANUALILLUSTRATEDPARTS LISTBURNER ASSEMBLY25,000 BTU/HR MODELThis list contains replaceable parts used in your furnace. When ordering

Page 19

26201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®ILLUSTRATEDPARTS LISTBURNER ASSEMBLY40,000 BTU/HR MODELThis list contains replaceable parts used in

Page 20

27201839OWNER’S MANUALILLUSTRATEDPARTS LISTBLOWER ASSEMBLY25,000 BTU/HR MODELThis list contains replaceable parts used in your furnace. When ordering

Page 21

28201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®ILLUSTRATEDPARTS LISTBLOWER ASSEMBLY40,000 BTU/HR MODELThis list contains replaceable parts used in

Page 22

29201839OWNER’S MANUALNOTES___________________________________________________________________________________________________________________________

Page 23

3201839OWNER’S MANUALLOCAL CODES UNPACKING1. Remove furnace from carton.2. Remove all protective packaging ap-plied to furnace for shipment.3. Remove

Page 24

LIMITED WARRANTYDYNAVENT GAS WALL FURNACEDESA International warrants this product to be free from defects in materials and components for one (1) year

Page 25

4201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®6" MinimumAdjacentSideWallCeilingFinished Floor, Carpet, Tile, etc.12"Minimum12" Minim

Page 26

5201839OWNER’S MANUALCREATING WALL OPENINGAND MOUNTING FURNACERemove furnace front cover. Remove thetwo screws at the lower edges of front cover.Lift

Page 27

6201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT®6. Attach thermostat to thermostat mount-ing plate with screws provided (see Fig-ure 4). IMPORTANT: N

Page 28

7201839OWNER’S MANUAL10. Feed thermostat wires from attic tofurnace through 1/2" hole in ceilingwall plate.11. Connect thermostat wires from atti

Page 29

8201839DIRECT-VENT PROPANE/LP GAS HEATERDYNAVENT® WARNING: Never use an openflame to check for a leak. Apply amixture of liquid soap and waterto all j

Page 30 - INTERNATIONAL

9201839OWNER’S MANUAL CAUTION: Never connect heater directly to the propane/LP supply.This heater requires an external regulator (not supplied). Insta